Self Consistent for Ge DGMOS
Closed | Responses: 0
I am currently trying to simulate the Band structure for a Ge DGMOS (with thickness 4nm) using self consistent calculation at a particular Bias Voltage. However the simulator is unable to complete …
http://nanohub.org/answers/question/1013
-
what kind of new research can be done by this tool? any exercise? in details..plz
Closed | Responses: 0
http://nanohub.org/answers/question/1009
-
can we simulate the band structure of graphene?
Closed | Responses: 1
http://nanohub.org/answers/question/967
-
Why do I not see option for choosing different crystal directions for bulk materials?
Closed | Responses: 1
http://nanohub.org/answers/question/914
-
Does simulation assume 300K?
Closed | Responses: 1
Is it possible to calculate band structure at different temp?
http://nanohub.org/answers/question/894
-
No output for self-consistent calculation
Closed | Responses: 0
Hi, I ran the tool for self-consistent calculation but I didn't obtain any result. It seems the tool does not work for this type of job. However, for non-self-consistent it works correctly. I …
http://nanohub.org/answers/question/861
-
differences between sp3s* and sp3d5s* models
Closed | Responses: 1
In this version of bandstrlab, the sp3s* model is not implemented (there is only one model, i.e. the sp3d5s*). It would be interesting to have that model to compare the differences between the sp3s* …
http://nanohub.org/answers/question/838
-
Strain Tight-Binding model
Closed | Responses: 0
I would like to know how this tool accounts the strain in TB Hamiltonian. Does it alter both the on-site and off diagonals elements? I would truly appreciate if you could help me out.
http://nanohub.org/answers/question/833
-
Bulk Si eff. mass vs. biaxial Strain
Closed | Responses: 2
Hello there, I was simulating Strain sweep on Bulk Si. I applied biaxial strain from -0.015 to 0.015 in [001] direction. I am interested in hole effective mass change as a function of strain. For …
http://nanohub.org/answers/question/832
-
No Output
Closed | Responses: 1
Hi there, It seems that the tool is not working...I was able to get some output couple of hours back but now it shows only a bunch of log files everytime I simulate anything. Tried restarting + …
http://nanohub.org/answers/question/828
-
why the duplicated charge distriboution under low bias gate is not same as the paper?
Closed | Responses: 1
I'm trying to duplicate " Band structure effect in silicon Nanowire electron transport" paper results for N-MOS, but I couldn't obtain the same result. In the case of Vg= 0, the charge dispersion …
http://nanohub.org/answers/question/790
-
Doping the Nanowire
Closed | Responses: 0
Hello, I'm beginner at using this tool. would you please let me know that we can dope the nanowire (channel) itself? thanks
http://nanohub.org/answers/question/789
-
Time for running on steele is far too long compared with nanohub.
Closed | Responses: 0
http://nanohub.org/answers/question/784
-
How to get visual results
Open | Responses: 1
I run with default parameters and get no visual results for bandstructure.
http://nanohub.org/answers/question/752
-
Can not see any results in the drop down menu.
Closed | Responses: 0
Hello, When I simulate the tool e.g. UTB default simulation, after completion of the simulation I can not find any outputs .In the results drop down menu input deck, backend code log, times …
http://nanohub.org/answers/question/733
-
Tool is not usable right now!
Open | Responses: 2
Hello, When I use any default setting of the tool -except of the bulk case - then I do not get any results. After clicking on "Simulate" I get the "Results": "Input Decks", "Backend BSLAB(OMEN) …
http://nanohub.org/answers/question/727
-
The tool does not run
Closed | Responses: 0
Hi, I cannot run the tool: rectangular nanowire band structure calculation. Michael.
http://nanohub.org/answers/question/723
-
It seems the tool does not work.
Closed | Responses: 0
It seems the tool does not work. I have made several trials on different structures (bulk/nanowires with the default parameters) but no result was displayed. Could you please check this issue? Thank …
http://nanohub.org/answers/question/718
-
The tool with all default settings (and one for circular nanowire) is not giving any results. The end result is a text file and no E/K, band structures plots.
Closed | Responses: 0
http://nanohub.org/answers/question/716
-
Does a positive value of epsilon correspond to tensile strain?
Open | Responses: 1
http://nanohub.org/answers/question/694