2% biaxial strain Ge, promen at the Gamma point
Closed | Responses: 0
Dear all, When I simulate the bandstructure of Ge with high strain (2%), I get a discontinuity at the Gamma point, and therefore the effective masses are not correctly calculated. Can you improve …
https://nanohub.org/answers/question/1080
-
8,10 nm thickness UTB with default values gives error
Closed | Responses: 1
When I tried to simulate UTB and double gate devices with 10 nm silicon thickness by using default values gives error... Thank you
https://nanohub.org/answers/question/485
-

Abhijeet Paul
Abhijeet Paul is a Device Engineer at GLOBALFOUNDRIES USA, located at Albany. He is currently working on the device analysis, electrical characterization, modeling, TCAD and electrical targetting for …
https://nanohub.org/members/15437
-
Abnormal Termination of DGMOS UTB Self-Consistent Simulation
Closed | Responses: 0
When running an Ultra-thin body MOSFET simulation with the job type set to "Calculate the UTB band-structure self consistently [for 1 gate bias point]," and all other simulation parameters set to the …
https://nanohub.org/answers/question/1100
-
Abort
Closed | Responses: 2
To terminate a simulation, the abort button is not working.
https://nanohub.org/answers/question/414
-
Any cahnce you can include the DOS from the E(k) curves for a 1D Kronig Penny model?
Open | Responses: 1
https://nanohub.org/answers/question/318
-
atomic coordinates file should have the right file extension *.pdb so one can read it into a local visualizer right away
Open | Responses: 2
The ability to ownload a coorinate file is existing now. However the file comes back as a t *.txt file. It if ame back with the right extension, my local machine could immediately use the file. …
https://nanohub.org/answers/question/248
-

Benjamin P Haley
Ben received his B.S. in Physics from Purdue in 1998. He worked for Cummins Engine Co and Intel before attending graduate school at UC Davis. He received a Masters in Engineering Applied Science in …
https://nanohub.org/members/17286
-
biaxial strain in bulk produces no results
Open | Responses: 3
Starting from scratch with a new simulation I am just turning on bi-axial strain in the bulk simulation mode and I get not simulation results.
https://nanohub.org/answers/question/220
-
bulk bandstructure: k-axis scale
Open | Responses: 2
It seems that the bulk bandstructure shows E-k along L->Gamma->X->UK->Gamma. If so, the k-scale does not seem to be correct. The distance between Gamma and X appear to be correct (2pi/a0), but the …
https://nanohub.org/answers/question/553
-
Bulk Si eff. mass vs. biaxial Strain
Closed | Responses: 2
Hello there, I was simulating Strain sweep on Bulk Si. I applied biaxial strain from -0.015 to 0.015 in [001] direction. I am interested in hole effective mass change as a function of strain. For …
https://nanohub.org/answers/question/832
-
Can not see any results in the drop down menu.
Closed | Responses: 0
Hello, When I simulate the tool e.g. UTB default simulation, after completion of the simulation I can not find any outputs .In the results drop down menu input deck, backend code log, times …
https://nanohub.org/answers/question/733
-
can we simulate the band structure of graphene?
Closed | Responses: 1
https://nanohub.org/answers/question/967
-
code crashes when 8nm triangular cross section nanowires are entered
Open | Responses: 3
code crashes when 8nm triangular cross section nanowires are entered crashes both in the electronic structure calculation as well as charge-selfconsistent calculation. Error message in the Output …
https://nanohub.org/answers/question/277
-
Confinement Effective mass
Closed | Responses: 1
Dear Admins, I am interested in calculating the effective mass along the confinement direction for nanowire geometries. Can this be done using Bandstrlab or is there another tool for it? Thanks and …
https://nanohub.org/answers/question/1110
-
Could k be expressed by kx ky kz?
Open | Responses: 2
I do not really know the meaning of "effective k" in the result figure.(the square root of kx ky kz?) This tool can show a table of k-E. Is this possible to show the "kx ky kz E" in the final result …
https://nanohub.org/answers/question/191
-
differences between sp3s* and sp3d5s* models
Closed | Responses: 1
In this version of bandstrlab, the sp3s* model is not implemented (there is only one model, i.e. the sp3d5s*). It would be interesting to have that model to compare the differences between the sp3s* …
https://nanohub.org/answers/question/838
-
Does a positive value of epsilon correspond to tensile strain?
Open | Responses: 1
https://nanohub.org/answers/question/694
-
Does simulation assume 300K?
Closed | Responses: 1
Is it possible to calculate band structure at different temp?
https://nanohub.org/answers/question/894
-
Doping the Nanowire
Closed | Responses: 0
Hello, I'm beginner at using this tool. would you please let me know that we can dope the nanowire (channel) itself? thanks
https://nanohub.org/answers/question/789