Tags: tool:dda

All Categories (1-20 of 22)

  1. How can I simulate Zinc Oxide in this method and what data i should upload for correct simulation? Please help and send me the detailed process.

    Closed | Responses: 1

    http://nanohub.org/answers/question/1895

  2. Does DDA method useful for the study of optical properties of semiconductor nanoparticle like zinc oxide embedded in dielectric polymer like PVP?

    Closed | Responses: 1

    http://nanohub.org/answers/question/1894

  3. Uploading dielectric constants into nanoDDSCAT?

    Open | Responses: 1

    I have complex dielectric constants for aluminum at given frequencies and was hoping to upload this into nanoDDSCAT, but unsure of the proper format or values to put into the...

    http://nanohub.org/answers/question/1819

  4. Why do I get only one point after running the simulation

    Open | Responses: 1

    I am trying to simulate nanorods for different aspect ratios, but after running the simulation, the graph shows only one point instead of a curve after setting the spectral window 400 - 700 nm....

    http://nanohub.org/answers/question/1637

  5. Why do I get only one point after running the simulation

    Closed | Responses: 1

    I am trying to simulate nanorods for different aspect ratios, but after running the simulation, the graph shows only one point instead of a curve after setting the spectral window 400 - 700 nm....

    http://nanohub.org/answers/question/1636

  6. Nearfield not working?

    Closed | Responses: 1

    I tried to do nearfield calculation, but the initialization always sets the parameter to 0, even if choosen in the menue.

    Is there any explanation for this?

    Can I generate...

    http://nanohub.org/answers/question/1592

  7. How can one normalize the E-Field intensity?

    Closed | Responses: 1

    More specifically, what is the initial Electric Field intensity (E0)2 of DDSCAT? 
    I want to create a normalized E-field intensity data map http://nanohub.org/answers/question/1500

  8. limiting storage

    Closed | Responses: 2

    Hello,

    I want to run a Nearfield generating simulation using DDSCAT, but i could not get the final results for limited storage. What should i do? Thanks.

    http://nanohub.org/answers/question/1444

  9. I keep receiving an error after I run my simulations on a single cylinder.

    Closed | Responses: 1

    Reason: 
    "The third parameter for Cylinder must have a value of 1 or 2 or 3." 

    I've done this test multiple times with the three different...

    http://nanohub.org/answers/question/1437

  10. Simulation error considering MXNX,MXNY,MXNZ

    Closed | Responses: 3

    Hello!

    I tried a simulation of a gold nanorod with size 41.1nm X 14.3nm (SHPAR1=26.8, SHPAR=14.3) with shape file: Cylinder with End-Caps. 

    But it crushed every time at...

    http://nanohub.org/answers/question/1430

  11. axes label and the zero point

    Closed | Responses: 2

    It would be helpful to position the axes labels at the end of the each axis. The current display is not clear.

    Also the zero point is printed as a small number in scientific notation...

    http://nanohub.org/answers/question/1403

  12. output file to simulate in matlab

    Closed | Responses: 1

    Do you guys have a matlab code that will allow me to use the target output file to simulate the 3D field so that i can mess with the colors of the intensity?

    http://nanohub.org/answers/question/1386

  13. Results log zoom in/out issue

    Closed | Responses: 1

    I noticed that when i was zooming in and out of the electric field (3d field) results log that the whole page scrolls up and down. Could you fix this little issue please.

    http://nanohub.org/answers/question/1385

  14. How can I change the Intensity scale?

    Closed | Responses: 3

    I would like to be able to see small changes in the intensity display. The electric field displays in just one color right now because there is very little variation in the intensity. I would...

    http://nanohub.org/answers/question/1382

  15. Stop running and no output

    Closed | Responses: 2

    When I use “Remote Parellel DDSCAT with Wavelength“option to run simulation, program will stop running simulate after 3-5 hours and create no output. Why could this happen?

    http://nanohub.org/answers/question/1380

  16. Can the simulation save data for future use?

    Closed | Responses: 1

    After running various simulations I wondered if the program can save the data obtained which then can be retrieved at a different time. For example if I were to publish a paper using your...

    http://nanohub.org/answers/question/1378

  17. How soon will the software be able to set the rotation of the object relative to the incident light?

    Open | Responses: 1

    I know that the option is hidden for now, “working on a gui based method to set the rotation of the object relative to the incident light.” I would like to know if it is possible to...

    http://nanohub.org/answers/question/1370

  18. Is there a way to change the polarization direction for the x axis to the y or z?

    Open | Responses: 2

    In the code I see ****define incident polarizations **** (0,0) (1,0) (0,0) = Polarization state e01 (k along x axis) Lets say I would want to observe the polarization of the object from a...

    http://nanohub.org/answers/question/1364

  19. can the Storage limit be increased?

    Closed | Responses: 3

    I am currently running some simulations and I would like to know if the storage for the ddscat tool be increased to 5 GB. This would allow more detailed simulations to be obtained.

    http://nanohub.org/answers/question/1360

  20. why does the 3D field electric field feature complie all previous simulations?

    Open | Responses: 2

    After doing a few simulations I noticed that in the 3D electric field feature seemed to keep previous simulations and I can not have it focus on one. I did unpress the ALL button but previous...

    http://nanohub.org/answers/question/1351