Problem launching job error
Closed | Responses: 2
Hello, I didn't change any default setting, but the tool is not performing the simulation. Bahare
http://nanohub.org/answers/question/796
-
Error clarification
Closed | Responses: 3
Hello, I'm getting the following error when I run a simulation: can't read "total vstep" : no such variable while executing "expr $total_vstep" (file …
http://nanohub.org/answers/question/507
-
How to do simulation on OMEN nanowire tool?
Open | Responses: 3
I have changed some input values and tried to simulate the structure but, it was taking around 3 hours to get simulated. Is there easy way to simulate nanowire structure using OMEN Nanowire tool?
http://nanohub.org/answers/question/504
-
How is the continuous doping density profile implemented in omenwire?
Open | Responses: 1
Hi, I understand that to mimic the contacts we enforce a high doping density in the source/drain extension regions, and it is easy to do so in a continuum formulation, like the effective mass …
http://nanohub.org/answers/question/462
-
Why does the potential show a singularity at the location where the boundary condition changes from Dirichlet to Neumann?
Closed | Responses: 3
At the gate side, there is a change of boundary condition from Dirichlet to Neumann as we move from the gate to the insulator. Mathematically, this will lead to a singularity in the solution when we …
http://nanohub.org/answers/question/332
-
boundary conditions for the poisson equation
Open | Responses: 2
I have simulated a case where Vg = 0.4V and Vd =0V. However, when I look at the potential plot, it appears that the potential at the boundary where the gate is 0V. Is it simply a plotting error, or …
http://nanohub.org/answers/question/320
-
analytical expression for the poisson solve
Open | Responses: 1
May I know what is the rational behind the use of the analytical expression given in the answer I asked about the convergence criteria. In particular, is the analytical formula based on the …
http://nanohub.org/answers/question/316
-
convergence criteria
Open | Responses: 2
In the input deck, the poisson convergence criterion is stated as 1e-3. What exactly is the convergence criteria used in omenwire? How much additional computational time will I need if I decrease …
http://nanohub.org/answers/question/305
-
fermi level
Open | Responses: 2
In determining the electron density, what fermi levels did you use at the source and drain? Thanks, George
http://nanohub.org/answers/question/304
-
Default voltage values need be changed.
Open | Responses: 2
With the default device specifications, it seems that the default nanowire has a threshold voltage of ~ 0.6V. So, to drive the device into deep ON state, one should apply gate voltage, probably …
http://nanohub.org/answers/question/246
-
OMEN Nanowire Supporting Document
23 Feb 2009 | Downloads | Contributor(s): SungGeun Kim, Gerhard Klimeck, Mathieu Luisier
This material supplements the first-time user guide for OMEN Nanowire with details concerning the limitation of the tool at large gate voltage. At large gate voltage, the calculations of the drain …
http://nanohub.org/resources/6315
-

Benjamin P Haley
Ben received his B.S. in Physics from Purdue in 1998. He worked for Cummins Engine Co and Intel before attending graduate school at UC Davis. He received a Masters in Engineering Applied Science in …
http://nanohub.org/members/17286
-

Shawn Rice
Shawn received his M.S. in Information Technology from Purdue University in 2004. With over 10 years of web development experience, his skills and interest run the gamut from server-side programming …
http://nanohub.org/members/8780
-

Gerhard Klimeck
Gerhard Klimeck is the Director of the Network for Computational Nanotechnology at Purdue University and a Professor of Electrical and Computer Engineering. He guides the technical developments and …
http://nanohub.org/members/3482